BS 1363-1:2016 specifies specifications for thirteen A fused plugs having insulating sleeves online and impartial pins, for family, advertisement and lightweight business reasons, with specific connection with security in basic use. The plugs are appropriate for the relationship of transportable home equipment, sound-vision apparatus, luminaires, and so on. in a.c. circuits merely, working at voltages now not exceeding 250 V r.m.s. at 50 Hz. extra requisites are incorporated for plugs appropriate for electrical car charging. specifications are targeted for plugs incorporating a fuse hyperlink conforming to BS 1362:1973. The plugs could be rewirable or non-rewirable whole with versatile cable. different types of plugs are particular protecting basic and tough use. Rewirable plugs are meant to be used with versatile cables conforming to the proper components of BS EN 50525 (see Annex H), having conductor cross-sectional parts from 1/2 mm2 to 1.5 mm2 inclusive.

Show description

Read Online or Download 13 A Plugs, Socket-outlets and Adaptors: Specification for Rewirable and Non-rewirable 13 A Fused Plugs BS 1363 PDF

Similar nonfiction_2 books

Raman Microscopy: Developments and Applications

Raman-microscopy is among the strongest and flexible analytical instruments that could be utilized to a wide selection of fields together with fabrics technology, geology, biology, medication, the humanities and forensic technological know-how. This the 1st ebook committed totally to the topic, delivering an authoritative and finished insurance of the entire box.

J.V.Stalin Works

The works of this era take care of the consolidation of the socialist kingdom system,the coverage of the Soviet govt at the nationwide query, the construction and strengthening of the pink military, and armed forces technique and strategies within the interval of international armed intervention and civil conflict.

Wisconsin deaths at Shiloh

This can be a copy of a e-book released earlier than 1923. This booklet can have occasional imperfections akin to lacking or blurred pages, bad photographs, errant marks, and so forth. that have been both a part of the unique artifact, or have been brought by means of the scanning technique. We think this paintings is culturally vital, and regardless of the imperfections, have elected to convey it again into print as a part of our carrying on with dedication to the protection of published works all over the world.

Extra resources for 13 A Plugs, Socket-outlets and Adaptors: Specification for Rewirable and Non-rewirable 13 A Fused Plugs BS 1363

Sample text

The link is to be replaced without disturbing the terminals or conductor terminations in so far as this is possible. At the conclusion of the final cycle and without disturbance, the plug shall be subjected to a temperature rise test in accordance with Clause 16. The measured temperature rise values shall not exceed those values given in Table 4. --`,,`-`-`,,`,,`,`,,`--- After the test, inspection by normal or corrected vision, without additional magnification, shall show no changes evidently impairing further use, such as cracks, deformation, or the like.

NOTE 2 For small helical springs and the like, and for parts exposed to abrasion, a layer of grease may provide sufficient protection against rusting. Such parts are only subjected to the test if there is doubt about the effectiveness of the grease film and the test should then be made without previous removal of the grease. 1 Clamp type (screwless) terminals shall pass the electrical and thermal stresses occurring in use. 1 Compliance shall be checked by the following tests. The rewirable plug shall be wired and mounted for test in accordance with Clause 16.

Shall be used for the calibration. 05 W; b) the temperature difference between the fuse contact clips does not exceed 2 °C. 1. 5 If the associated clearance is less than 3 mm, the minimum groove width may be reduced to one-third of this clearance. The methods of measuring creepage distances and clearances are indicated in the following Examples 1 to 11. These cases do not differentiate between gaps and grooves or between types of insulation. The following assumptions are made: — any recess is assumed to be bridged with an insulating link having a length equal to the specified width X and being placed in the most unfavourable position (see Example 3); — where the distance across a groove is equal to or larger than the specified width X, the creepage distance is measured along the contours of the groove (see Example 2); — creepage distances and clearances measured between parts which can assume different positions in relation to each other, are measured when these parts are in their most unfavourable position.